38
Key combinations - special functions
General The following functions can be called up by pressing buttons simultaneously or repeatedly 
on the MagicWave and TransTig control panels.
Displaying the 
software version, 
operating time 
and coolant flow
To display the software version:
while pressing and holding the Mode button, press the left parameter 
selection button.
The software version appears on the digital displays.
Display operating time:
press the left parameter selection button again
The operating time records the actual arc burning time since starting 
for the first time.
For example: "654 | 32.1" = 65,432.1 hours = 65,432 hours | 6 mins
NOTE The operating time display is not suitable as a -basis for cal-
culating hiring fees, guarantee, etc.
Display coolant flow (only in conjunction with a cooling unit with the 
flow watchdog option):
press the left parameter selection button again
The current coolant flow of the cooling unit is shown in l/min (CFL = 
Coolant Flow)
If the coolant flow is less than 0.7 l/min, the power source switches 
off after the end of the time specified in welding parameter C-t and 
the error message "no | H2O" is shown.
To exit, press the Mode button.