EasyManua.ls Logo

Frymaster LOV - Page 17

Frymaster LOV
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.3.3 AIF (Auto Intermittent Filtration) Actuator Board Pin Positions with RTD
Sensor
Connector From/To Harness PN
Pin
#
Function Voltage
Wire
Color
1 Ret + (Open) 24VDC Black
2 Ret – (Closed) 24VDC Red
3 Ret Position Purple
J1 FV Return N/A
4 Ground White
1 Ground White
FV AIF RTD
2 FV - Temp Red
3 Ground White
DV AIF RTD
4 DV - Temp Red
5
6
7
8
9
DV – Press Sw (Gas)
Pressure Switch
(Gas)
10
FV – Press Sw (Gas)
11 Locator Vat #5
12 Locator Vat #4
13 Locator Vat #3
14 Locator Vat #2
Locator Pin
15 Locator Vat #1
Black
J2
Locator
8074551 (FV)
8074550 (DV)
16 Locator Signal Black
1 Ret + (Open) 24VDC Black
2 Ret – (Closed) 24VDC Red
3 Ret Position Purple
J3 DV Return N/A
4 Ground White
1 Ground Black
2 CAN Lo Red
3 CAN Hi White
4 5VDC+ 5VDC Black
5 24VDC 24VDC Red
J4
MIB J2 or
AIF J5
8074547
AIF Board
Communication
and Power
6 Ground White
1 Ground Black
2 CAN Lo Red
3 CAN Hi White
4 5VDC+ 5VDC Black
5 24VDC 24VDC Red
J5
AIF J4 or
ATO J10
8074547
AIF Board
Communication
and Power
6 Ground White
1 Drain + (Open) 24VDC Black
2 Drain – (Closed) 24VDC Red
3 Drain Position Purple
J6 FV Drain N/A
4 Ground White
1 Drain + (Open) 24VDC Black
2 Drain – (Closed) 24VDC Red
3 Drain Position Purple
J7 DV Drain N/A
4 Ground White
17