Problem Probable Causes Corrective Action
M2007 display
shows chk pan.
A. Filter pan is not fully set into fryer.
B. Missing filter pan magnet.
C. Defective filter pan switch.
A. Pull filter pan out and fully
reinsert into fryer.
B. Ensure the filter pan magnet is
in place and if missing replace.
C. If the filter pan magnet is fully
against the switch and
computer continues to display
chk pan, switch is
possibly defective.
M2007 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
M2007 computers may be
programmed to display in either
Fahrenheit or Celsius. Press and
hold 3and 4simultaneously until
code appears. Enter 1658.
The computer displays OFF. This
toggles the temperature from F° to
C° or vice versa. Turn the
computer on to check temperature
and see the temperature scale. If
the desired scale is not displayed,
repeat.
M2007 display
shows hot-hi-1.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
This in an indication of a
malfunction in the temperature
control circuitry, including a
failure of the high-limit thermostat.
M2007 display
shows HI-LIMIT.
Computer in high-limit test mode.
This is displayed only during a test
of the high-limit circuit and
indicates that the high-limit has
opened properly.
M2007 display
shows low temp.
Frypot temperature is between 180°F
(82°C) and 315°F (157°C).
This display is normal when the
fryer is first turned on while in the
melt cycle mode. To bypass the
melt cycle press and hold a #2
product button under the LCD
display until a chirp is heard. The
alarm will chirp and the computer
displays EXIT MELT alternating
with YES NO. Press the #1 YES
button to exit melt. It may appear
for a short while if a large batch of
frozen product is added to the
frypot. If the display never goes
out, the fryer is not heating.