5-28
F30
F31
Analog Output [FMA] (Voltage adjustment and Function)
F31 allows you to output monitored data (such as the output frequency or output
current) to terminal [FMA] as an analog DC voltage that can be adjusted with F30
for the meter scale.
Voltage adjustment (F30)
Adjust the output voltage level within the range of 0 to 200%, supposing the
monitored amount of the monitor selected with function code F31 as 100%.
Function (F31)
F31 specifies what is output to the analog output terminal [FMA].
In the case of FRN4.0C1
-4**, the actual output level for input powe
r
will be multiplied by 108% while the reference motor rating is 3.7 kW.