3-14
Table 3.10 List of FRENIC-Mini Function Codes
Function code
group
Function code Function Description
F codes F00 to F51 Fundamental func-
tions
To be used for basic motor running.
E codes E01 to E99 Extension terminal
functions
To be used to select the functions of the
control circuit terminals.
To be used to set functions related to
the LED monitor display.
C codes C01 to C52 Control functions of
frequency
To be used to set application functions
related to frequency settings.
P codes P02 to P99 Motor parameters To be used to set special parameters for
the motor capacity, etc.
H codes H03 to H98 High performance
functions
To be used for high added value func-
tions and complicated control, etc.
J codes J01 to J06 Application functions To be used for PID control.
y codes y01 to y99 Link functions To be used for communications
Refer to Chapter 5 "FUNCTION CODES" for details on the function codes.
Function codes that require simultaneous keying
To change data for function codes F00 (Data protection), H03 (Data initialization), and H97 (Clear
alarm data) simultaneous keying operation is necessary--
+ keys or + keys. This
prevents data from being lost by mistake.
Changing, validating, and saving function code data when the motor is running
Some function code data can be changed while the motor is running and some cannot. Further,
amongst the function codes whose data can be changed while the motor is running, there are some
for which the changes can be validated immediately and others for which they cannot. Refer to the
"Change when running" column in Chapter 5, Section 5.1 "Function Code Tables."