Chapter 2 Description of Functions
79
Optimize Y axis graph
Arrange the Y axis display position and scale of the displayed channels without overlapping by
channel. Reset the amplitude setting to the initial value.
Y axis display position: Ch1=100 and the value increments by +100 for the subsequent
channels.
Scale: Set the scale value so that the maximum value can be within two
grids. (Minimum unit: 50)
Detect waveform peak
Move Cursor A to the maximum value of the selected channel automatically. If there are two or
more peaks, the cursor moves to the earliest one.
Display range in one DIV
Set the time to be displayed in one waveform monitor screen.
Ttrace back, Historical trace:
(1ms, 5ms, 10ms, 20ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 5min,
10min)
Real-time trace:
(10ms, 20ms, 50ms, 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min, 5min, 10min, 20min,
30min, 60min)
Color setting
The color setting data is held. When obtaining the waveform, you can change the color setting.
Ch line
Line color and line type of the trace data of the selected channel
Cursor line A
Select the line color, line type and line thickness of Cursor line A.
Color line B
Select the line color, line type and line thickness of Cursor line B.
Trigger line
Select the line color, line type and line thickness of the trigger line.
Grid line
Select the line color, line type and line thickness of the grid line.
Graph background color setting
Select the waveform monitor background color.
The settings of the trace line of each CH are as below:
Color
Type of line Thickness