Table 8: PROFINET Specifications
Item
Description
Conformance Tested
PROFINET V2.31 Certificate
Protocol Level
RT (real-time)
RT Conformance Class
Class B
Netload Class
III
I/O Cycle Time
Min 1ms
I/O Input Size
Max 32 input words, user configurable
I/O Output Size
Max 32 output words, user configurable
MRP
Media Redundancy Protocol Client
DCP
Discovery, set station name, set IP address
LLDP
Yes
I&M
I&M0
Alarms
Plug, Pull
Number of Controllers
Allows access to only 1 controller
Table 9: Applicable Inverters
Series
Capacity
ROM version
FRENIC-Ace
All capacities
0300 or higher
Table 10: Environmental Specifications
Item
Description
Operating Environment
Indoors, less than 1000m above sea level, do not expose to direct
sunlight or corrosive / explosive gasses
Operating Temperature
-10 +50°C (+14 +122°F)
Storage Temperature
-40 +85°C (-40 +185°F)
Relative Humidity
20% 90% (without condensation)
Vibration
5.9m/s
2
(0.6G) or less (10 55Hz)
Cooling Method
Self-cooled
RoHS (Lead free)
Yes