MHT258a (Engl.)5-51
Interface
Parameter setting
To allocate the fixed/passing point 1 signal to the control output terminal, set (17) to the system para. Set (18) for the fixed/passing point 2.
Related items
Selection of output form
Output form can be set by basic para. 62 to 65.
Basic parameter 62 to 65
Para. Name Setting range Initial value Change
62 Fixed/passing point detection 0 : Fixed point
1 : Passing point off àon
2 : Passing point on à off
0 Always
63 Fixed/passing point detection position 1 0 to ±79,999,999 (in increments of 1)
[x unit q’ty]
0 Always
64 Fixed/passing point detection position 2 0 to ±79,999,999 (in increments of 1)
[x unit q’ty]
0 Always
65 Fixed point detection range (zone) 0 to ±79,999,999 (in increments of 1)
[x unit q’ty]
100 Always
Valid or invalid of position detection function
Position detection function such as fixed/passing point 1 can be effective after origin return end.
Basic parameter 67
Para. Name Setting range Initial value Change
67 Position detection function valid/invalid 0 : Valid after origin return 1 : Always 0 Always
5.7.6 Override
This function changes the current motor speed.
While override effective (43) signal is turned on, the motor speed is variable by a scale factor specified by override 1/2/4/8 up to 1.5
times the current speed.
Weighting of scale factor corresponding to override 1/2/4/8 can be changed by basic para.
This function is effective for any rotation command except for torque control, pulse train input (pulse train ratio 1 or 2).
This function will not be effective after the ON edge of interrupt input in interrupt positioning.
Interface
Fixed/passing point 1 (17)
Fixed/passing point 2 (18)
ON/OFF : Automatically turns on or off according to the current position
Override effective (43)
Override 1 (44)
Override 2 (45)
Override 4 (46)
Override 8 (47)
+24V
P24
M24
2.2k
+24V

Table of Contents

Related product manuals