EasyManua.ls Logo

Fuji Electric RYS201S3-VVS - High Voltage, Overvoltge; Amp Heat, Amplifier Overheat; Encoder Communication Error

Fuji Electric RYS201S3-VVS
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT258a (Engl.)9-12
(g) High voltage, overvoltge
Touch panel display
Detection (example)
The DC intermediate voltage in the amplifier is higher than the upper limit.
Cause, check and remedy
(h) Amp heat, amplifier overheat
Touch panel display
Detection (example)
The temperature of cooling-fins of the amplifier is above 100 [°C]
• Cause, check and remedy
The ambient temperature for the amplifier should be below +55 [°C]
(i) Encoder communication error
Touch panel display
Detection (example)
The communication is not made between 16-bit serial encoder and amplifier.
Cause, check and remedy
The encoder wiring may be detached or disconnected.
The serial communication is performed at 4[Mbps] of data rate. Do not extend the wiring by connecting several short cables.
Connect the encoder by option cable or specified cables.
The encoder wiring has about 5[V] of voltage amplitude. Do no install it in a location where a strong electric or magnetic field exists.
Overvoltage (Hv)
Contact us
Power capacitor is turned ON/OFF
on same line.
Occurs when turning on power. Power supply voltage may be higher than specified.
Study a use of AC reactor.
Braking resistor is connected. Study a use of external braking resistor (0.2 [kW] max.).
Braking resistor is free from
disconnect.
Check the resistance of braking resistor.
For resistance of braking resistor, see 10.6.