MHT258a (Engl.)11-15
(2) MICREX-SX
FB (function block) for acquiring a current position output (see 5.4.5).
RD_REQ : Request current position read [BOOL]
RD_ANS : Answer current position read [BOOL]
ANS_BIT1 : Amplifier data bit 1 [BOOL]
ANS_BIT2 : Amplifier data bit 2 [BOOL]
RD_COM : Read command to amplifier [BOOL]
RD_RUN : Reading [BOOL]
RD_OK : Normal end of read [BOOL]
RD_NG : Abnormal end of read [BOOL]
ABS_POS : Current position data [DINT]
Turning on RD_REQ executes a sequence of current position acquisition.
The current position is outputted in [DINT] form to ABS_POS terminal.
Connect each terminal to the amplifier.
RD_COM : Current position output command (control assign No. 56)
RD_ANS : OUT2
ANS_BIT1 : OUT3 of amplifier terminals
ANS_BIT2 : OUT4
11.3 Control block diagram
The control block diagram for RYS-V type amplifier is shown on the next page.
(1) Override
Validated by assigning the control assign terminals [CONTn] to signals.
Set value, value set at system para. No. Signal name
43 Override valid
44 Override 1
45 Override 2
46 Override 4
47 Override 8
(2) Manual feed
The speed of manual forward or reverse revolution can be selected from 8 levels.
X3 X2 X1 Speed
OFF OFF OFF NREF terminal (speed command voltage)
OFF OFF ON 1
OFF ON OFF 2
OFF ON ON 3
ON OFF OFF 4 of manual feed speed (basic para.)
ON OFF ON 5
ON ON OFF 6
ON ON ON 7
Validated by assigning the signals to control assign terminals [CONTn]
Signal function No. Functional name
51 X1
52 X2
53 X3
RD_COM
RD_RUN
RD_OK
RD_NG
ABS_POS
RD_REQ
RD_ANS
A
NS_BIT1
A
NS_BIT2
ABS_ENC_1
ABS_ENC

Table of Contents