MHT258a (Engl.)6-10
6.2 Peripheral device
This section explains the peripheral devices to be directly connected to the amplifier.
6.2.1 Speed command, torque command
The gain or offset of speed command [NREF] terminal and torque command [TREF] terminal can be adjusted..
System parameter 63 to 66
Para. Name Setting range Initial value Change
63 Speed command gain ±0.10 to ±1.50 times (in increments of 0.01) 1.00 Always
64 Speed command offset –2000 to + 2000 (in increments of 1) (Individual) Always
65 Torque command gain ±0.10 to ±1.50 times (in increments of 0.01) 1.00 Always
66 Torque command offset –200 to + 200 (in increments of 1) (Individual) Always
- Speed control - Position control
Speed command voltage
* : System para. 63 setting
+10V
5000r/min
−5000r/min
−10V
(×1.5)
        (×1.0)
        (×0.1)
     
Speed
Torque command voltage
* : System para. 65 setting
+9V
(Max. torque)
(Max. torque)
−9V
(×1.5)
        (×1.0)
        (×0.1)
     
Output torque

Table of Contents