MHT258a (Engl.)5-11
Parameter setting
To allocate the forward command [FWD] signal to the control input terminal, set (2) to the system para. (set (3) for Reverse command [REV])
If these signals are not allocated to the control input terminal, these signals are deemed "always off."
Related items
Changeover of acceleration/deceleration time
The acceleration and deceleration time of motor can be set by basic para. 21 to 24. The acceleration time and deceleration time can be
set independently.
Speed
Time
OFFON
OFF
Forward command
[FWD]
Basic para. 22
Basic para. 24
Basic para. 21
Basic para. 23
Basic parameter 21 to 24
Para. Name Setting range. Initial value Change
21 Acceleration time 1 0.000 to 99.999s (in 0.001s steps) 0.100 Always
22 Deceleration time 1 0.000 to 99.999s (in 0.001s steps) 0.100 Always
23 Acceleration time 2 0.000 to 99.999s (in 0.001s steps) 0.100 Always
24 Deceleration time 2 0.000 to 99.999s (in 0.001s steps) 0.100 Always
The acceleration time is set by the basic para. 21 or 23, regardless of rotational direction.
Acceleration time 1 or 2 (basic para. 21 or 23) can be selected by system para. ACC0 [ACC0] setting.
[ACC0] (14) Acceleration time Deceleration time
OFF
ON
Basic para. 21 Basic para. 22
Basic para. 23 Basic para. 24
To allocate the ACC0 [ACC0] signal to the control input terminal, set (14) to the system para. If this signal is not allocated to the control
input terminal, this signal is deemed "always off."
Rotation speed
In speed control, seven kinds of motor speed can be set by the basic para. 1 to 7.
Basic parameter 1 to 7
Para. Name Setting range Initial value Change
1 Manual feed speed 1 0.01 to Max. speed [r/min] (in 0.01 steps) 100.00 Always
2 Manual feed speed 2 0.01 to Max. speed [r/min] (in 0.01 steps) 500.00 Always
3 Manual feed speed 3 0.01 to Max. speed [r/min] (in 0.01 steps) 1000.00 Always
4 Manual feed speed 4 0.01 to Max. speed [r/min] (in 0.01 steps) 100.00 Always
5 Manual feed speed 5 0.01 to Max. speed [r/min] (in 0.01 steps) 100.00 Always
6 Manual feed speed 6 0.01 to Max. speed [r/min] (in 0.01 steps) 100.00 Always
7 Manual feed speed 7 0.01 to Max. speed [r/min] (in 0.01 steps) 100.00 Always
Motor speed can be changed by combining the on/off status of X1, X2 and X3 terminals.
The speed change is possible even while motor is rotating.

Table of Contents

Related product manuals