Data setting range
Incre-
0.0 (Cancel), 0.1 to 400.0
H51 0 to 240: Output an AVR-controlled voltage
(for 200 V class series)
0 to 500: Output an AVR-controlled voltage
(for 400 V class series)
1 V N Y2
H52 Non-linear V/f Pattern 2
(Frequency)
(Voltage)
0.0 (Cancel), 0.1 to 400.0 0.1 Hz N Y 0.0
0 to 240: Output an AVR-controlled voltage
(for 200 V class series)
0 to 500: Output an AVR-controlled voltage
(for 400 V class series)
0.00 to 3600 0.01 s Y Y 6.00
(Initial frequency setting)
1: Last UP/DOWN command value on
(Lower limiting
frequency)
0: Limit by F16 (Frequency limiter: Low)
and continue to run
1: If the output frequency lowers below the
one limited by F16 (Frequency limiter:
Low), decelerate to stop the motor.
0.0 (Depends on F16 (Frequency limiter:
1: Enable (Lengthen the deceleration time
to three times the specified time under
voltage limiting control.) (Compatible with
the original FVR-Micro
FVR
…
AS1S-
…
)
4: Enable (Torque limit control: Disable
force-to-stop processing.)
H70 Overload Prevention
Control
0.00: Follow deceleration time specified by
F08/E11
0.01 to 100.0, 999 (Cancel)
0.01 Hz/s
Y Y 999
H71 Deceleration
Characteristics
0: Disable
1 to 9999 (in units of 10 hours)
H79 Preset Startup Count for
Fluctuation Damping
Gain for Motor 1