(H codes continued)
Code
Name
Data setting range
Incre-
ment
Unit
Change
when
running
Data
copying
De
fault
setting
H89
Electronic Thermal
Overload Protection for
Motor
(Data retention)
0: Disable
1: Enable
Y
Y
1
H91
PID Feedback Wire
Break Detection
(Terminal [C1])
0.0: Disable alarm detection
0.1 to 60.0: After the specified time, cause
alarm
0.1 s Y Y 0.0
H92
Continuity of (P)
Running *1
(I)
0.000 to 10.000 times; 999
0.001
tim
es
Y
Y1
Y2
999
H93
0.010 to 10.000 s; 999
0.001
s
Y
Y1
Y2
999
H94
Cumulative Run Time of
Motor 1
0 to 9999 (in units of 10 hours) N N
H95
DC Braking
(Brakin
g response
mode)
0: Slow
1: Quick
Y
Y
0
H96
STOP Key Priority/Start
Check Function
Data STOP key priority Start check function
0: Disable Disable
1: Enable Disable
2: Disable Enable
3: Enable Enable
Y
Y
0
H97
Clear Alarm Data
0: Disable
1: Clear alarm data
Y
N
0
H98
Protection/Maintenance
Function
(Mode selection)
0 to 31 (decimal)
Bit 0: Lower the carrier frequency
automatically (0: Disable; 1: Enable)
Bit 1: Detect input phase loss
(0: Disable; 1: Enable)
Bit 2: Detect output phase loss
(0: Disable; 1: Enable)
Y Y 3