Details of function
Control input function
When function setting is “Operation/Stop” mode 1
In the case of “Edge” input:
Function
setting
Rotary SW on External
Input and Output PCB
External input Input signal Command
46-00 1
External Input and
Output PCB
CN313
Off → On Operation
On → Off Stop
Operation
Stop
Remote controller
On
Off
Indoor unit
On
CN313
In the case of “Pulse” input:
Function
setting
Rotary SW on External
Input and Output PCB
External input Input signal Command
46-00 1
External Input and
Output PCB
CN313 Pulse Operation
CN314 Pulse Stop
On
On
Off
Operation
Stop
Remote controller
On
Off
Indoor unit
CN313
CN314
NOTES:
The last command has priority.
The indoor units within the same remote controller group operates in the same mode.
- 152 -
12-4. Wall mounted type (KGTE, KGTF, KMCE, KMCF, KETE, KETE-B, KETF, and KETF-
B)
12. External input and output
2-UNIT
MULTI-SPLIT TYPE
2-UNIT
MULTI-SPLIT TYPE

Table of Contents

Other manuals for Fujitsu AOYG14KBTA2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG14KBTA2 and is the answer not in the manual?

Fujitsu AOYG14KBTA2 Specifications

General IconGeneral
BrandFujitsu
ModelAOYG14KBTA2
CategoryAir Conditioner
LanguageEnglish

Related product manuals