6-3. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: AOYG14KBTA2
Indoor unit connecting
capacity
Outdoor temperature
Indoor temperature
16.0 °CDB 18.0 °CDB 20.0 °CDB 22.0 °CDB 24.0 °CDB
kBtu/h °CDB °CWB TC IP TC IP TC IP TC IP TC IP
21
-15.0
-16.0 3.30 1.34 3.30 1.37 3.20 1.40 3.10 1.43 3.00 1.46
-10.0 -11.0 3.80 1.39 3.70 1.42 3.60 1.45 3.50 1.48 3.40 1.51
-5.0 -7.0 4.20 1.44 4.10 1.47 4.00 1.50 3.90 1.53 3.80 1.56
0.0 -2.0 5.30 1.46 5.20 1.49 5.10 1.52 4.90 1.55 4.80 1.58
5.0 3.0 5.70 1.47 5.60 1.50 5.50 1.53 5.30 1.56 5.20 1.59
7.0 6.0 5.80 1.63 5.60 1.67 5.50 1.70 5.40 1.73 5.20 1.77
10.0 8.0 5.80 1.32 5.60 1.34 5.50 1.37 5.40 1.40 5.20 1.43
15.0 10.0 5.80 1.20 5.60 1.23 5.50 1.25 5.40 1.28 5.20 1.30
20.0 15.0 5.80 0.94 5.60 0.96 5.50 0.98 5.40 1.00 5.20 1.02
24.0 18.0 5.80 0.84 5.60 0.86 5.50 0.88 5.40 0.89 5.20 0.91
19
-15.0
-16.0 3.30 1.34 3.30 1.37 3.20 1.40 3.10 1.43 3.00 1.46
-10.0 -11.0 3.80 1.39 3.70 1.42 3.60 1.45 3.50 1.48 3.40 1.51
-5.0 -7.0 4.20 1.44 4.10 1.47 4.00 1.50 3.90 1.53 3.80 1.56
0.0 -2.0 5.30 1.46 5.20 1.49 5.10 1.52 4.90 1.55 4.80 1.58
5.0 3.0 5.70 1.47 5.60 1.50 5.50 1.53 5.30 1.56 5.20 1.59
7.0 6.0 5.80 1.63 5.60 1.67 5.50 1.70 5.40 1.73 5.20 1.77
10.0 8.0 5.80 1.32 5.60 1.34 5.50 1.37 5.40 1.40 5.20 1.43
15.0 10.0 5.80 1.20 5.60 1.23 5.50 1.25 5.40 1.28 5.20 1.30
20.0 15.0 5.80 0.94 5.60 0.96 5.50 0.98 5.40 1.00 5.20 1.02
24.0 18.0 5.80 0.84 5.60 0.86 5.50 0.88 5.40 0.89 5.20 0.91
18
-15.0
-16.0 3.30 1.34 3.30 1.37 3.20 1.40 3.10 1.43 3.00 1.46
-10.0 -11.0 3.80 1.39 3.70 1.42 3.60 1.45 3.50 1.48 3.40 1.51
-5.0 -7.0 4.20 1.44 4.10 1.47 4.00 1.50 3.90 1.53 3.80 1.56
0.0 -2.0 5.30 1.46 5.20 1.49 5.10 1.52 4.90 1.55 4.80 1.58
5.0 3.0 5.70 1.47 5.60 1.50 5.50 1.53 5.30 1.56 5.20 1.59
7.0 6.0 5.80 1.63 5.60 1.67 5.50 1.70 5.40 1.73 5.20 1.77
10.0 8.0 5.80 1.32 5.60 1.34 5.50 1.37 5.40 1.40 5.20 1.43
15.0 10.0 5.80 1.20 5.60 1.23 5.50 1.25 5.40 1.28 5.20 1.30
20.0 15.0 5.80 0.94 5.60 0.96 5.50 0.98 5.40 1.00 5.20 1.02
24.0 18.0 5.80 0.84 5.60 0.86 5.50 0.88 5.40 0.89 5.20 0.91
16
-15.0
-16.0 3.30 1.34 3.30 1.37 3.20 1.40 3.10 1.43 3.00 1.46
-10.0 -11.0 3.80 1.39 3.70 1.42 3.60 1.45 3.50 1.48 3.40 1.51
-5.0 -7.0 4.20 1.44 4.10 1.47 4.00 1.50 3.90 1.53 3.80 1.56
0.0 -2.0 5.30 1.46 5.20 1.49 5.10 1.52 4.90 1.55 4.80 1.58
5.0 3.0 5.70 1.47 5.60 1.50 5.50 1.53 5.30 1.56 5.20 1.59
7.0 6.0 5.80 1.63 5.60 1.67 5.50 1.70 5.40 1.73 5.20 1.77
10.0 8.0 5.80 1.32 5.60 1.34 5.50 1.37 5.40 1.40 5.20 1.43
15.0 10.0 5.80 1.20 5.60 1.23 5.50 1.25 5.40 1.28 5.20 1.30
20.0 15.0 5.80 0.94 5.60 0.96 5.50 0.98 5.40 1.00 5.20 1.02
24.0 18.0 5.80 0.84 5.60 0.86 5.50 0.88 5.40 0.89 5.20 0.91
14
-15.0
-16.0 3.30 1.34 3.30 1.36 3.20 1.39 3.10 1.42 3.00 1.45
-10.0 -11.0 3.80 1.39 3.70 1.42 3.60 1.45 3.50 1.47 3.40 1.50
-5.0 -7.0 4.20 1.44 4.10 1.47 4.00 1.50 3.90 1.53 3.80 1.56
0.0 -2.0 5.30 1.45 5.20 1.48 5.10 1.51 4.90 1.54 4.80 1.57
5.0 3.0 5.70 1.46 5.60 1.49 5.50 1.52 5.30 1.55 5.20 1.58
7.0 6.0 5.80 1.63 5.60 1.67 5.50 1.70 5.40 1.73 5.20 1.77
10.0 8.0 5.80 1.32 5.60 1.34 5.50 1.37 5.40 1.40 5.20 1.43
15.0 10.0 5.80 1.20 5.60 1.23 5.50 1.25 5.40 1.28 5.20 1.30
20.0 15.0 5.80 0.94 5.60 0.96 5.50 0.98 5.40 1.00 5.20 1.02
24.0 18.0 5.80 0.84 5.60 0.86 5.50 0.88 5.40 0.89 5.20 0.91
NOTES:
TC: Total Capacity (kW), IP: Input Power (kW)
Values mentioned in the table are based on the following conditions:
Power source of specifications: 230 V
Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
2 or more indoor units should be connected.
The total ability of connected a indoor unit is from 14,000 Btu/h up to 21,000 Btu/h.
Input in the table are calculated based on the maximum indoor unit input combinations.
- 318 -
6-3. Heating capacity 6. Capacity table
OUTDOOR UNIT
AOYG14-18KBTA2
OUTDOOR UNIT
AOYG14-18KBTA2