En-9
•Installsleevesintoanyholesmadeinthewallsforwiring.
Otherwise, a short circuit could result.
•Installagroundleakagebreaker.Inaddition,installthe
ground leakage breaker so that the entire AC main power
supply is cut off at the same time. Otherwise, electric
shockorrecouldresult.
•Installagroundleakagebreaker.
If a ground leakage breaker is not installed, it may cause
electricshockorre.
•Alwaysconnectthegroundcable.
Improper grounding work can cause electric shocks.
•Installtheremotecontrolcablessoasnottobedirect
touched with your hand.
•Performwiringworkinaccordancewithstandardssothat
the air conditioner can be operated safely and positively.
•Connecttheconnectioncablermlytotheterminal
board.Imperfectinstallationmaycauseare.
CAUTION
•Groundtheunit.
Do not connect the ground cable to a gas pipe, water
pipe, lightning rod, or a telephone ground cable.
Improper grounding may cause electric shock.
•Donotconnectpowersupplycabletothetransmissionor
remote control terminals, as this will damage the product.
•Never bundle the power supply cable and transmission
cable together. Bundling these cables together will cause
miss operation.
•WhenhandlingPCB,staticelectricitychargedinthebody
may cause malfunction of the PCB. Follow the cautions
below:
•Establishagroundfortheindoorandoutdoorunitsand
peripheral devices.
•Cutpower(breaker)off.
•Touchmetalpartoftheindoorandoutdoorunitsfor
more than 10 seconds to discharge static electricity
charged in the body.
•Donottouchterminalsofpartsandpatterns
implemented on PCB.
(
4
Left rear piping)
Drainhose
Connection cable
(Power supply cable)
Connection pipe
Connection cable
(Transmission and
Remote control cable)
Connect the piping
• Pipingworkcanbemadeeasierbylayingout,shaping,
and temporarily fastening the connection pipe and
connection cable beforehand.
6. ELECTRICAL WIRING
]
WARNING
•Electricalworkmustbeperformedinaccordancewiththis
Manualbyapersoncertiedunderthenationalorregional
regulations. Be sure to use a dedicated circuit for the unit.
An insufficient power supply circuit or improperly
performed electrical work can cause serious accidents
suchaselectricshockorre.
•Before starting work, check that power is not being
supplied to the indoor unit and outdoor unit.
•Use the included connection cables and power cables
or ones specified by the manufacturer. Improper
connections, insufficient insulation, or exceeding the
allowablecurrentcancauseelectricshockorre.
•For wiring, use the prescribed type of cables, connect
them securely, making sure that there are no external
forces of the cables applied to the terminal connections.
Improperly connected or secured cables can cause
serious accidents such as overheating the terminals,
electricshock,orre.
•Do not modify the power cables, use extension cables,
or use any branches in the wiring. Improper connections,
insufcientinsulation,orexceedingtheallowablecurrent
cancauseelectricshockorre.
•Matchtheterminalboardnumbersandconnectioncable
colors with those of the outdoor unit. Erroneous wiring
may cause burning of the electric parts.
•Securely connect the connection cables to the terminal
board. In addition, secure the cables with wiring holders.
Improper connections, either in the wiring or at the ends
of the wiring, can cause a malfunction, electric shock, or
re.
•Alwaysfastentheoutsidecoveringoftheconnection
cable with the cable clamp. (If the insulator is chafed,
electric leakage may occur.)
•Securelyinstalltheelectricalboxcoverontheunit.
Animproperlyinstalledelectricalboxcovercancause
seriousaccidentssuchaselectricshockorrethrough
exposuretodustorwater.