Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
116
P 0F
SSMM
00 2 0F00
MM
00
-
Controller Module#
m
(
zz
) SCU Fault
<
pppppppppppp ssssssssss rrrrr
>
These messages are
notified when "Parts
Error" is enabled for
Error Severity Level in
the event notification
setting.
They are not notified
during maintenance
operations.
CM SCU is disconnected.
SS
: Component subtype
MM
: CM module ID (10 – 11)
m
: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 10
SSMM
00 2 1000
MM
00
-
CA Slot#
S
-
V
(
zz
) (on CM#
m
) Fault <
pppppppppppp
ssssssssss rrrrr
>
CA is disconnected.
SS
: Component subtype
MM
: CA module ID (40 – 7F)
S
: CA slot number (0 – 1)
V
: Device number (0 – 1)
zz
: CA type
m
: CM number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 11
SSMM
0
p
2 1100
MM
0
p
-
CA Slot#
S
-
V
(
zz
) (on CM#
m
) Port#
P
Fault
<
pppppppppppp ssssssssss rrrrr
>
CA port is disconnected.
SS
: Component subtype
MM
: CA module ID (40 – 7F)
p
: Device port number (0 – 1)
S
: CA slot number (0 – 1)
V
: Device number (0 – 1)
zz
: CA type
m
: CM number (0 – 1)
P
: Port number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
P 1700
MM
0
p
2 1700
MM
0
p
-
FC16G SFP+ CA Slot#S(
zz
) (on CM#
m
) Port#
P
Fault
<
pppppppppppppppp ssssssssssssssss rrrr
oooooooo
>
CA SFP+ is disconnected.
MM
: CA module ID (40 – 7F)
p
: Device port number (0 – 1)
S
: CA slot number (0 – 1)
zz
: CA type
m
: CM number (0 – 1)
P
: Port number (0 – 1)
pp...
: Component number
ss...
: Serial number
rr...
: Version
oo...
: Additional information
Event type
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID
Trap
Sensor
Info
Lower: Description