Page #124 background imageLoading...
Page #124 background image
Table
3-12
  
Problems
resolved
in
XCP
2210
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
140212-015
xx xIf
the
version(8)
command
is
executed
after
replacing
the
CPU
memory
unit
lower
(CMUL),
XSCF
unit
(XSCFU)
or
the
motherboard
unit
(MBU),
the
state
of
"Current
Bank"
and
"Reserve
Bank"
is
wrongly
displayed.
[Example]
-
Before
replacing
CMUL
XSCF>
version
-c
xcp
BB#00-XSCF#0
(Master)
XCP0
(Reserve):
2210
XCP1
(Current):
2210
-
(Wrong)
After
replacing
CMUL
XSCF>
version
-c
xcp
BB#00-XSCF#0
(Master)
XCP0
(Reserve):
2210
XCP1
(Current):
2210
-
(Right)
After
replacing
CMUL
XSCF>
version
-c
xcp
BB#00-XSCF#0
(Master)
XCP0
(Current):
2210
XCP1
(Reserve):
2210
There
is
no
effective
workaround.
It
will
not
affect
the
system
as
it
is
only
a
problem
of
the
command
output.
[How
to
restore]
Re-execute
the
flashupdate(8)
command.
RTIF2-
140212-017
xAfter
removing
SPARC
M10-4S
or
crossbar
boxes
(XBBOX)
with
the
initbb(8)
or
the
replacefru(8)
commands,
if
the
XSCF
network
(host
and
domain
names,
SSCP,
IP
address,
routing,
name
server)
is
setup
and
the
applynetwork(8)
command
is
executed,
the
"An
internal
error
has
occurred.
Please
contact
your
system
administrator"
error
message
is
output
and
the
XSCF
network
parameters
are
not
enabled.
There
is
no
effective
workaround.
[How
to
restore]
After
re-connecting
or
replacing
the
removed
SPARC
M10-4S
or
XBBOX,
set
up
the
XSCF
network
again.
RTIF2-
140212-018
xx xIn
the
REMCS
customer
information
input
screen,
if
any
of
the
following
two-byte
characters
are
input
in
the
two-byte
input
field,
input
error
message
may
be
output.
-
The
leading
character
corresponds
to
A1xx
of
the
EUC
code.
-
The
trailing
character
corresponds
to
xxA1
of
the
EUC
code.
Do
not
input
the
two-byte
characters
at
the
beginning
and
end
of
the
character
strings,
which
produce
errors.
RTIF2-
140212-019
x x x When
turning
on
the
input
power,
the
voltage
reading
of
the
power
supply
unit
(PSU)
fails
and
the
PSU
error
"Hardware
access
error"
may
be
mistakenly
detected
and
the
PSU
is
degraded.
There
is
no
effective
workaround.
[How
to
restore]
Ignore
this
error
log.
To
dissolve
the
degraded
state
of
the
PSU,
turn
off
the
input
power
and
turn
it
on
again.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015110

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals