3-12
  
Problems
resolved
in
XCP
2210
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
140212-001
xIn
a
system
configuration
with
several
SPARC
M10-4S
(system
boards),
after
a
system
board
in
a
physical
partition
has
been
degraded
due
to
failure,
when
the
system
board
is
attempted
to
be
replaced
with
the
replacefru(8)
command,
the
system
board
is
recognized
as
being
running
and
the
attempt
of
replacement
fails
with
the
following
error
message:
[Warning:028]
BB#XX
cannot
be
replaced
because
the
PSB
in
the
BB
that
you
indicated
is
running.
Similarly,
an
attempt
to
initialize
the
degraded
system
board
with
the
initbb(8)
command
fails
with
the
following
error
message:
Hardware
error
occurred
by
initial
diagnosis.
This
symptom
occurs
if
the
system
board
is
in
the
following
state,
when
the
showhardconf(8)
or
the
showboards(8)
command
is
executed:
[Example]
In
case
PSB#01-0
(BB#01)
has
been
degraded.
XSCF>
showhardconf
...
*
BB#01
Status:Deconfigured;
...
XSCF>
showboards
-a
PSB
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
---
------------
-----------
----
----
----
-------
--------
01-0
00(01)
Assigned
n
n
n
Passed
Faulted
After
removing
the
degraded
system
board
from
the
physical
partition
with
the
deleteboard(8)
command,
execute
either
the
replacefru(8)
or
the
initbb(8)
command
to
replace
or
remove
the
system
board.
[Example]
XSCF>
deleteboard
-c
unassign
01-0
After
replacing
the
system
board,
assign
the
system
board
to
the
physical
partition
using
the
addboard(8)
command
and
follow
the
maintenance
procedures
to
add
it
in
the
physical
partition.
[Example]
XSCF>
addboard
-c
assign
-p
0
01-0
RTIF2-
140212-010
xx xIf
[Ctrl]+[C]
is
executed
in
the
middle
of
executing
the
setsnmp(8),
setsnmpusm
(8)
or
the
setsnmpvacm(8)
commands,
SNMP
cannot
be
set
up
using
the
above
commands
after
that.
In
such
a
case,
the
error
message
"configuration
being
changed
by
another
user"
may
be
displayed.
There
is
no
effective
workaround.
Chapter
3
 
Information
on
Software 109

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals