Table
3-15
  
Problems
resolved
in
XCP
2090
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
131112-002
x Suppose
that
the
system
uses
a
crossbar
box
and
contains
two
or
more
physical
partitions
(PPARs)
each
consisting
of
2BB
or
more.
In
this
system,
if
a
hardware
failure
that
affects
all
the
PPARs
occurs,
the
failed
part
is
degraded
such
that
the
PPAR
reactivation
processing
may
fail,
causing
all
the
PPAR
power
supplies
to
remain
turned
off.
There
is
no
effective
workaround.
The
failed
parts
are
degraded.
Power
on
the
PPAR
again.
RTIF2-
131112-003
xx x
If
the
testsb(8),
diagxbu(8),
or
flashupdate
-c
sync
command
is
executed
during
the
execution
of
the
flashupdate(8)
command,
the
error
log
"FMEM
serious
error"
is
registered,
and
the
testsb(8),
diagxbu(8),
or
flashupdate
-c
sync
command
may
fail.
Do
not
execute
the
testsb(8),
diagxbu(8),
or
flashupdate
-c
sync
command
while
the
flashupdate(8)
command
is
being
executed.
To
confirm
the
completion
of
the
flashupdate(8)
command,
execute
the
showlogs
event
command
and
then
check
for
the
following
message.
XCP
update
has
been
completed
(XCP
version=xxxx:last
version=yyyy)
RTIF2-
131112-008
x x x Suppose
that
the
error
log
"SCF
Diagnosis
error
on
System
backup
memory"
is
registered,
which
is
related
to
the
PSU
backplane
(PSUBP)
or
XSCF
interface
unit
(XSCFIFU).
The
FRU
of
the
error
log
registered
immediately
after
that
error
log
may
not
be
correct.
In
this
case,
any
one
of
the
following
messages
is
displayed
to
indicate
that
the
FRU
PSUBP
or
XSCFIFU
is
not
correct.
Msg:
SCF
Diagnosis
initialize
RTC
FRU:
PSUBP
or
XSCFIFU
or
Msg:
SCF
Diagnosis
error
on
XXXX
FRU:
PSUBP
or
XSCFIFU
XXXX
indicates
any
of
the
following
FRUs:
CPU,
L2
cache,
SDRAM,
RTC,
SPI
FMEM,
NAND
There
is
no
effective
workaround.
Replace
the
FRU
as
follows.
For
SPARC
M10-1:
FRU:
/MBU
For
SPARC
M10-4:
FRU:
/BB#00/CMUL
For
SPARC
M10-4S:
FRU:
/BB#xx/CMUL
or
FRU:
/XBBOX#xx/XSCFU
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015118

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals