Problems
resolved
in
XCP
2070
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130228-001
xx xIf
a
physical
partition
(PPAR)
is
powered
on
again
after
the
PPAR
is
forcefully
powered
off
with
the
poweroff
-f
command
while
starting
up
Oracle
Solaris,
"Unable
to
connect
to
Domain
Service
providers"
is
output
to
the
OS
console
and
Oracle
Solaris
may
not
be
started.
Power
on
the
PPAR
again
with
the
poweron(8)
command
after
disconnecting
the
power
of
the
PPAR
with
the
poweroff(8)
command.
If
Oracle
Solaris
does
not
start
up
even
after
that,
reset
the
XSCF
after
disconnecting
the
power
of
the
PPAR
and
then
power
on
the
PPAR
again.
RTIF2-
130516-001
xx xIn
a
system
configuration
for
which
power
supply
interlocking
with
ETERNUS
is
set,
ETERNUS
is
not
powered
on
even
if
the
power
is
turned
on
from
the
power
switch
located
on
the
operation
panel
of
the
SRARC
M10
system.
Turn
on
the
power
in
one
of
the
following
ways:
-
XSCF
command,
poweron(8)
command
-
Menu
on
the
XSCF
Webpage
-
Automatic
power
turning
on
with
schedule
settings
RTIF2-
130709-001
xIn
the
state
where
the
physical
partition
(PPAR)
is
powered
on,
when
switching
of
the
master
XSCF
occurs,
it
may
take
time
before
the
standby
XSCF
switches
to
the
master
XSCF.
As
a
result,
the
following
error
may
occur.
Master
switch
synchronization
timeout
There
is
no
effective
workaround.
[How
to
restore]
-
If
the
error
occurs
during
execution
of
the
flashupdate(8)
command
when
the
power
to
the
PPAR
is
on:
Turn
off
the
power
to
the
PPAR,
and
then
execute
the
flashupdate(8)
command
again.
-
If
the
error
occurs
during
execution
of
the
switchscf(8)
command
when
the
power
to
the
PPAR
is
on,
or
if
the
error
occurs
due
to
an
XSCF
failure
(process
down
etc.)
when
the
power
to
the
PPAR
is
on:
Perform
recovery
of
the
SPARC
M10-4S
chassis
for
which
the
"XSCF
hang-up
is
detected"
error
log
has
been
registered
by
using
either
of
the
following
methods.
-
Execute
the
replacefru(8)
command
to
replace
the
CPU
memory
unit
lower
(CMUL)
or
XSCF
unit
(XSCFU).
-
Power
off
and
on
the
CPU
memory
unit
lower
(CMUL)
or
the
XSCF
unit
(XSCFU).
Chapter
3
 
Information
on
Software 129

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals