3-17
  
Problems
resolved
in
XCP
2070
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130711-001
x When
you
perform
maintenance
of
the
SPARC
M10-4S
by
executing
the
replacefru(8)
or
addfru(8)
command,
the
"FMEM
serious
error"
error
log
may
be
registered
and
the
replacefru(8)
or
addfru(8)
command
may
fail.
Also,
when
you
turn
on
the
power
to
the
physical
partition
(PPAR)
during
the
execution
of
the
flashupdate(8)
command,
similarly,
the
"FMEM
serious
error"
error
log
may
be
registered
and
the
flashupdate(8)
command
may
fail.
For
details,
see
"Response
to
"FMEM
serious
error"
of
SPARC
M10-4S
(RTIF2-130711-001)."
RTIF2-
130716-001
xx x
When
you
update
the
PCI
expansion
unit
firmware
by
executing
the
ioxadm(8)
command,
a
"LINKCARD
I2C
error"
error
may
occur.
There
is
no
effective
workaround.
However,
if
both
of
the
conditions
below
can
be
confirmed,
the
update
of
the
PCI
expansion
unit
firmware
has
been
completed
normally.
In
this
case,
ignore
the
"LINKCARD
I2C
error"
error
message,
and
continue
the
operation.
-
The
update
of
the
PCI
expansion
unit
firmware
by
using
the
ioxadm(8)
command
has
been
completed
normally.
-
Executing
the
ioxadm
-v
list
command
displays
the
version
number
of
the
PCI
expansion
unit
firmware
that
has
been
specified
for
the
update.
RTIF2-
130801-001
x Even
if
you
execute
the
switchscf(8)
command,
the
XSCF
may
not
be
switched.
At
this
time,
the
master
XSCF
and
standby
XSCF
cannot
communicate
with
each
other,
and
the
redundancy
of
the
XSCF
is
not
maintained.
There
is
no
effective
workaround.
If
the
XSCF
is
not
switched
even
by
executing
the
switchscf(8)
command,
execute
the
replacefru(8)
command
to
perform
active
replacement
of
the
XSCF
unit
that
is
in
the
standby
chassis.
Also,
when
you
disconnect
the
XSCF
unit,
disconnect
and
then
connect
the
XSCF
BB
control
cable.
RTIF2-
130802-001
x x x When
you
specify
USB
memory
for
the
getflashimage(8)
command,
the
following
message
may
be
output
and
the
execution
of
the
command
may
fail.
Error:
Unable
to
mount
USB
device.
After
disconnecting
and
then
connecting
the
USB
memory,
execute
the
getflashimage(8)
command
again.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015130

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals