EasyManuals Logo

Fujitsu M10 Product Notes

Fujitsu M10
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
Table
3-17
  
Problems
resolved
in
XCP
2070
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
131112-016
xx xIf
you
use
the
deleteuser(8)
command
to
delete
a
user
account
for
which
an
SSH
user
public
key
is
registered,
it
is
deleted
but
the
user
public
key
is
not
deleted.
User
public
keys
will
continue
to
increase
in
number
such
that
it
may
not
be
possible
to
register
one
for
a
new
user
account.
Moreover,
if
a
user
account
with
the
same
name
is
registered
again,
the
SSH
user
public
key
registered
previously
is
set.
Before
deleting
a
user
account
with
the
deleteuser(8)
command,
execute
setssh
-c
delpubkey
-a
-u
to
delete
the
SSH
user
public
key
registered
for
the
user
account.
[How
to
restore]
Perform
the
following
procedure.
1.
Execute
the
adduser(8)
command
to
register
the
deleted
user
account
again.
2.
Execute
the
rebootxscf
-a
command
to
reset
the
XSCF,
or
turn
off
and
on
the
input
power.
3.
Execute
setssh
-c
delpubkey
-a
-u
to
delete
the
SSH
user
public
key.
4.
Execute
the
deleteuser(8)
command
to
delete
the
user
account.
RTIF2-
140623-001
x x x Even
when
the
snapshot(8)
command
is
executed,
it
does
not
collect
log
data
concerning
NTP-related
statistics.
There
is
no
effective
workaround.
This
problem
does
not
affect
system
operation.
Please
execute
the
following
steps:
1)
Remove
(Delete)
the
BB#x
from
a
system.
2)
Turn
off
the
breaker
of
the
BB#x.
3)
After
the
exchanged
device
is
connected
with
the
system,
turn
on

the
breaker
of
the
BB#x.
4)
Please
select[f:finish]
:
Please
execute
the
following
steps:
1)
After
the
added
device
is
connected
with
the
system,
please
turn
on

the
breaker
of
the
BB#x.
Response
to
"FMEM
serious
error"
of
SPARC
M10-4S
(RTIF2-130711-001)
Replacing
SPARC
M10-4S
When
replacing
the
SPARC
M10-4S
by
following
the
maintenance
menu
displayed
by
executing
the
replacefru(8)
command,
perform
Step
3
and
then
turn
on
the
input
power
to
the
target
SPARC
M10-4S
(BB#x).
Then,
after
waiting
for
50
minutes,
manually
enter
"f"
in
Step
4
to
perform
the
work.
Adding
SPARC
M10-4S
When
adding
the
SPARC
M10-4S
by
following
the
maintenance
menu
displayed
by
executing
the
addfru(8)
command,
perform
Step
1
and
then
turn
on
the
input
power
to
the
target
SPARC
M10-4S
(BB#x).
Then,
after
waiting
for
50
minutes,
manually
enter
"f"
in
Step
2
to
perform
the
work.
Chapter
3
 
Information
on
Software 137

Table of Contents