Table
3-21
  
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
121219-016
xx xAn
"internal
error"
may
occur
if
the
prtfru(8)
command
is
executed
while
powering
on/off
or
resetting
the
physical
partition
(PPAR).
Wait
for
the
power
on/off
or
reset
of
the
PPAR
to
complete
and
then
execute
the
prtfru(8)
command
again.
RTIF2-
121219-017
xIf
a
SPARC
M10-4S
chassis
is
powered
off
after
an
error
log
is
registered
because
a
memory
error
occurred
in
BB#00
or
BB#01,
the
same
error
log
may
be
registered
again.
There
is
no
effective
workaround.
RTIF2-
121219-018
x
In
a
system
in
which
two
or
more
SPARC
M10-4S
chassis
units
constitute
multiple
physical
partitions
(PPARs),
if
you
power
on
the
PPAR
after
switching
the
master
XSCF
as
a
result
of
any
of
the
following,
error
logs
of
"STICK
does
not
start
(CPU)",
"STICK
does
not
start
(MBC)",
or
"STICK
count
up
error"
may
be
registered,
causing
degradation
of
the
CPU
memory
units
(CMUU/CMUL).
-
Performing
firmware
update
-
Detecting
an
XSCF
failure
-
Executing
the
switchscf(8)
command
There
is
no
effective
workaround.
After
switching
of
the
master
XSCF
is
performed,
power
off
the
input
power
supply
of
all
SPARC
M10-4Ss
and
power
them
on
again,
without
powering
on
the
PPAR.
RTIF2-
121219-019
xx xWhen
a
PCI
card
is
inserted
to
or
removed
from
a
PCI
expansion
unit,
a
number
that
is
different
from
the
relevant
PCI
card
number
(PCI#)
is
displayed
in
the
log.
In
addition,
when
error
log
"PCICARD
failed"
is
registered
due
to
an
error
with
the
PCIe
slot
on
the
PCI
expansion
unit
or
the
PCI
card,
a
number
other
than
that
of
the
relevant
PCI
card
number
(PCI#)
is
displayed
in
the
error
log.
Read
it
as
the
number
obtained
by
subtracting
one
from
the
PCI
number
(PCI#)
displayed
in
the
log.
RTIF2-
130109-002
x
If
"Console
path
is
switched"
is
registered
in
the
event
log
of
a
system
in
which
the
physical
partition
(PPAR)
consists
of
multiple
system
boards
(PSBs),
the
PPAR-ID
may
have
an
invalid
value.
There
is
no
effective
workaround.
RTIF2-
130109-005
xx xIf
you
use
the
replacefru(8)
command
to
replace
a
power
supply
unit
(PSU),
"Indispensable
parts
are
not
installed
(PSU)"
may
be
registered
in
the
event
log.
This
is
an
error
log
that
is
registered
because
a
PSU
is
removed.
Ignore
it.
Chapter
3
 
Information
on
Software 151

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals