Page #166 background imageLoading...
Page #166 background image
Table
3-21
  
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130109-006
xIf
you
change
the
setting
information
of
the
power
supply
interlocking
function
while
the
standby
XSCF
is
in
failure
or
starting,
the
changed
setting
information
may
not
be
reflected
in
the
standby
XSCF
even
after
the
start
of
the
standby
XSCF
is
completed.
If
XSCF
switching
occurs
in
this
state,
the
master
XSCF
after
the
switching
may
not
be
able
to
achieve
power
supply
interlocking
based
on
the
changed
setting
information.
Disable
the
power
supply
interlocking
function,
and
then
configure
it
again
using
the
following
procedure:
1.
Execute
the
setremotepwrmgmt
-c
disable
command
to
disable
the
power
supply
interlocking
function.
2.
Save
the
management
file,
and
then
use
the
clearremotepwrmgmt(8)
command
to
initialize
the
setting
information.
-
If
the
standby
XSCF
is
starting,
execute
the
clearremotepwrmgmt(8)
command
after
the
start
is
completed.
-
If
the
standby
XSCF
is
in
failure,
use
the
replacefru(8)
command
to
replace
the
target
FRU,
and
then
execute
the
clearremotepwrmgmt(8)
command.
3.
After
the
start
of
the
standby
XSCF
is
completed,
execute
the
setremotepwrm gmt
-c
config
command
to
restore
the
setting
information
based
on
the
saved
management
file.
4.
Execute
the
setremotepwrmgmt
-c
enable
command
to
enable
the
power
supply
interlocking
function.
RTIF2-
130109-007
xx xIf
all
physical
partitions
(PPARs)
are
stopped
and
you
try
to
power
on
a
PPAR,
the
PPAR
may
not
be
powered
on
with
no
error
log
registered.
There
is
no
effective
workaround.
Tun
off
the
input
power
supply
and
turn
it
back
on
to
all
SPARC
M10
system
chassis
and
then
try
to
power
on
the
PPAR
again.
RTIF2-
130130-001
xxIf
you
turn
on
the
AC
when
the
system
configuration
has
no
CPU
memory
unit
upper
(CMUU),
a
"Hardware
access
error"
error
log
is
generated
for
CMUU.
The
same
phenomenon
occurs
when
you
add
or
replace
SPARC
M10-4S.
The
error
log
is
registered
because
no
CMUU
is
mounted.
So,
ignore
it.
RTIF2-
130212-001
xIf
the
power
save
operation,
which
is
set
by
the
setpparmode(8)
command,
is
"enabled,"
the
following
problems
may
occur.
-
A
hang-up
(heartbeat
function)
in
a
logical
domain
may
be
unable
to
be
detected.
-
If
the
CPU
core
resources
are
reduced
during
system
startup
(while
a
physical
partition
(PPAR)
is
operating),
the
PPAR
may
be
powered
off.
Set
the
power
save
operation
to
"disabled"
by
using
the
setpparmode(8)
command.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
March
2015152

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals