Table
3-5
  
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No. 1 4 4S Description Workaround
RTIF2-
130702-001
xxIf
the
following
applies,
"I/O
devices
error
detected"
is
detected
at
the
time
of
PPAR
power-on
and
control
domain
reboot:
In
SPARC
M10-4/M10-
4S,
the
CPU
memory
unit
upper
(CMUU)
is
added
to
a
configuration
that
has
been
operated
with
only
the
CPU
memory
unit
lower
(CMUL)
and
false
has
been
set
as
the
IOreconfigure
setting
of
the
physical
partition
(PPAR).
There
is
no
workaround
for
errors
that
are
detected
at
power-on
after
the
addition.
Making
the
following
setting
prevents
the
error
detection
that
occurs
every
time
the
PPAR
is
powered
on
or
the
control
domain
is
rebooted.
1.
After
starting
Oracle
Solaris,
execute
the
ldm
rm-io
command
to
delete
the
PCIe
root
complex
of
the
added
CMUU
from
the
configuration
of
the
control
domain.
2.
Execute
the
ldm
add-spconfig
command
to
save
the
constructed
logical
domain
configuration
to
the
XSCF.
RTIF2-
130710-001
x
If
XSCF
switching
is
performed
using
the
switchscf(8)
command,
in
rare
cases,
the
standby
XSCF
may
not
start.
There
is
no
effective
workaround.
[How
to
restore]
Turn
off
and
then
turn
on
the
input
power
supply
(AC
OFF/ON)
to
every
SPARC
M10-4S
or
execute
the
replacefru(8)
command
to
perform
pseudo
replacement
(replacement
work
without
replacing
any
parts)
of
the
SPARC
M10-4S
that
does
not
start.
RTIF2-
130711-003
x Before
active
replacement
of
the
XSCF
unit
of
the
crossbar
box
is
completed,
the
replacefru(8)
command
is
completed
normally.
When
you
use
the
replacefru(8)
command
to
replace
the
XSCF
unit,
the
following
message
may
appear
after
you
replace
the
XSCF
unit.
If
it
does,
wait
for
10
minutes,
and
then
enter
"f".
The
replacement
of
XBBOX#xx/XSCFU
has
completed
normally.[f:finish]
:
RTIF2-
130802-003
xWhen
you
replace
the
XSCF
unit
of
the
crossbar
box
by
using
the
replacefru(8)
command,
the
command
is
completed
normally,
but
the
following
error
log
may
be
registered.
The
suspected
location
indicated
by
this
error
log
is
incorrect.
SCF:Board
control
error
(link
failed)
Replace
the
XSCF
unit
of
the
same
crossbar
box
by
using
the
replacefru(8)
command
again.
If
you
have
turned
off
the
input
power
(AC
OFF)
during
the
replacement
work,
disconnect
and
then
connect
all
the
XSCF
BB
control
cables.
RTIF2-
130919-001
xIn
case
of
a
system
comprising
of
several
SPARC
M10-4S,
if
input
power
is
turned
off
and
on
(AC
OFF/ON)
on
a
number
of
SPARC
M10-4S
chassis,
while
some
other
slave
chassis
are
running,
the
physical
partitions
may
not
start.
When
performing
AC
OFF/ON,
do
so
on
all
the
chassis
comprising
a
system.
[How
to
Restore]
Turn
off
input
power
of
all
the
chassis
comprising
the
system
and
then
turn
on
the
input
power.
Chapter
3
 
Information
on
Software 45

Table of Contents

Other manuals for Fujitsu M10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu M10 and is the answer not in the manual?

Fujitsu M10 Specifications

General IconGeneral
BrandFujitsu
ModelM10
CategoryServer
LanguageEnglish

Related product manuals