EasyManua.ls Logo

Fujitsu MCE3064AP - Logical Unit Number; ERASE Command

Fujitsu MCE3064AP
175 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 38 C156-E142-02EN
4.6.1 Logical Unit Number
A value other than 0 is not supported for Logical Unit Number (LUN). It must always be 0.
4.6.2 ERASE command
Table 4.39 ERASE command
Bit
Byte
76543210
0 Operation Code (2Ch)
1 Logical Unit Number Reserved
2-5 Logical Block Address
6 Reserved
7-8 Transfer Length
9-11 reserved
The ERASE command erases data of the specified number of blocks from the specified logical
block address.
Logical Block Address specifies the head logical block address from which the ODD starts writing.
Transfer Length specifies the number of blocks to be transferred and written.
When Transfer Length is specified as 0, the command does not carry out data transfer. The
ERASE command erases no data of the blocks and ends normally.

Table of Contents