C156-E142-02EN 4 - 51
4.6.5.6 Timer & protect page
Table 4.66 Timer & protect page
Bit
Byte
76543210
0 PS 0 Page Code (1Ch)
1 Page Length (06h)
2 Reserved
3 Reserved Inactivity Time Multiplier
4 Reserved DISP SWPP
5-7 Reserved
Inactivity Time Multiplier indicates the minimum time from the end of an access command until
the ODD enters standby mode. Table 4.66 lists the relationship between the specified value and
time. When a value of X'1' to X'9' is specified, the command assumes X'A' and responds with
Recovered Error.
Table 4.67 Inactivity Time Multiplier value
Inactivity Time
Multiplier
Minimum time after the end of an access command until the ODD
enters standby mode.
0h Infinite
1h 125 ms
2h 250 ms
3h 500 ms
4h 1 s
5h 2 s
6h 4 s
7h 8 s
8h 16 s
9h 32 s
Ah 1 min
Bh 2 min
Ch 4 min
Dh 8 min
Eh 16 min
Fh 32 min