4 - 46 C156-E142-02EN
Read Retry Count must not be 3 or smaller. If a value of 3 or smaller is specified, the command
assumes 4 and reports Recovered Error.
Write Retry Count must not be a value other than 3. If a value other than 3 is specified, the
command assumes 3 and reports Recovered Error.
Write Retry operation is complicate and not always executed three times.
To assure media compatibility, the read-write error recovery page should be set to the default
value, except for diagnostics purposes.
The read-write error recovery page can be saved.
Table 4.55 Changeable values in the read-write recovery page
Bit
Byte
76543210
210010101
3 FFh
4-7 00h
8 FFh
9-11 00h
Table 4.56 Default values for the read-write recovery page
Bit
Byte
76543210
210000000
31Fh
4-7 00h
8 03h
9-11 00h