Notes on power management
Notes on power management
If your computer is equipped with power management (power-saving mode), the mon itor can fully
support this function. Here the monitor does not di stinguish between the individual energ y-saving
modes of the computer (standby mode, suspend mode and OFF mode), as it is capable of
immediately switching into the mode with the highest energy-saving effect.
Power consumption
Mode
State
Typical Maximum
Status LED
Power On –
maximum operation
Maximum brightness /
with USB and au dio
187 W < 200 W
Power On –
normal mode
Maximum brightness
/ without USB and
audio
57 W < 75 W
Energy Star
Factory settings,
without USB and
audio
33 W
–
EU Energy Label
Without USB and
audio
35 W
––
ECO Without USB and
audio
42.3 W 55 W
Readiness
(standby)
Without USB devices
connected
0.3 W < 0.5 W
Off Without USB devices
connected
0.29 W < 0.5 W
If the computer detects inactivity (no input) it sends a n appropriate signal to the monitor to
reduce the power consumption (power s aving mode). The status LED of the m onitor changes
colour to show the change in s tatus. ECO operation is the pre-set factory default.
Once an input is made at the computer the screen contents are restored.
For detailed information on how energy-saving mode operates, please refer to
the operating manual or technical manual of the computer.
For maximum energy efficiency, the ACR (Advanced Contrast Ratio)
OSD setting is activated by default. Deactivate the ACR function to
achieve an optimised screen appearance.