RX200 S6 Options Guide 33
Main memory
In the case of same number of ranks install the memory module with the
highest capacity into the slot with lowest number (e.g. 8GB 2Rx4 modules
(DIMM-1A) before 4GB 2Rx4 modules (DIMM-2A)).
In Mirrored Channel Mode and in Spare Channel Mode, memory modules of
different capacities may be mixed on a bank by bank basis.
The assignment of the DIMM slots to the memory banks and channels is
imprinted on the system board next to the DIMM slots.
5.2 Expanding the main memory
Ê Open the server as described in the chapter "Preparation" on page 25.
Ê Remove the air duct as described in the section "Removing the air duct" on
page 29.
Figure 6: Removing a memory module
Ê Press the securing clips on both sides of the memory slot concerned
outward.
Ê If the slot was equipped: pull the memory module out of the slot (2).
1
1
2