RX200 S6 Options Guide 39
Processors
6.2 Replacing the processor
V CAUTION!
Only processors of the same type may be used on the system board.
That means the number of the internal processor cores as well as the
primary clock and the FSB frequency have to be the same. For dual
operation, use a suitable multiprocessor operating system.
Ê Open the server as described in the chapter "Preparation" on page 25.
Ê Remove the air duct as described in the section "Removing the air duct" on
page 29.
Figure 11: Removing the heat sink
Ê Loosen the four screws of the heat sink in a crossover pattern.
Ê Loosen the heat sink carefully by turning it back and forth. Then lift it up and
off.
Ê Remove the residual thermal paste from the underside of the heat sink.
Ê Clean the underside of the heat sink using a lint-free cloth.