RX200 S6 Options Guide 41
Processors
Ê Close the processor holder (2).
Ê Lock the processor in the socket by returning the spring clip to its original
position (3).
Ê Apply a small amount of thermal paste to the upper side of the new
processor.
Ê Ensure a thin and even distribution of the thermal paste.
Ê Place the heat sink on the processor (see figure 10 on page 38).
Ê Fasten the heat sink by tightening the four screws in a crossover pattern.
Ê Reinstall the air duct as described in the chapter "Completion" on page 73.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter "Completion" on page 73.