26 Service Supplement RX600 S6
Replacement routines
4.3 Replacing the I/O riser card 
The I/O riser card is replaced the same way as a non-hot-plug controller. A 
description can be found in the Options Guide for this server.
4.4 Replacing the Remote Management Module 
The Remote Management Module (Intel® RMM3) is located on the I/O riser 
card. The Remote Management Module is delivered with the I/O riser card only 
and thus it can only be replaced with the complete I/O riser card.
4.5 Replacing the SAS/SATA RAID controller 
card 
Ê Open the server as described in section "Opening the server" on page 21
Figure 8: Replacing the SAS/SATA RAID controller card 
Ê Disconnect the HDD-activity cable (1) and both SAS cables (2) & (3) from 
the SAS/SATA RAID controller card.
Ê Open the slot lock and remove the defective SAS/SATA RAID controller 
card.
To install the new SAS/SATA RAID controller card follow the above steps in 
reverse.
/
0