RX600 S6 Service Supplement 31
Replacement routines
Figure 12: Removing the IDTEMP combo
Ê Unplug the I
2
C bus cable from the IDTEMP combo.
Ê Undo the screw (see arrow in figure above) and remove the defective
IDTEMP combo.
To install the new IDTEMP combo follow the above steps in reverse.
I In order to enable ServerView Operations Manager and ServerView
Installation Manager to identify the system, it is necessary to program the
chassis ID prom using the "ChassisIDProm Tool" after installing the new
IDTEMP combo.
This tool is available for download from the following Fujitsu Technology
Solutions support page:
http://partners.ts.fujitsu.com/com/service/intelservers/tools
For the Japanese market, follow the instructions provided separately.