3. INITIAL SETTINGS
3-2
3.2 How to Set External Equipment
The FELCOM 18 is set at the factory to accept the distress alert/received call unit IC-
305, up to three alarm units IC-306 and the SSAS alert unit IC-307. If the configuration
is different, change the setting to OFF as below.
1. Press the F8 key to show the [Setup] menu.
2. Press the 1 key to show the [System Setup] menu.
3. Press the ↓ key to select [Command Window], and then press Enter key to show
the [Command Window] screen.
4. Enter the [Enter JOB No.:], and then press the Enter key.
5. Enter the [PASSWORD:], and then press the Enter key.
[Main Menu] is highlighted.
6. Press the 1 and Enter keys in order.
Command Window screen
7. Press the number key for unit not connected.
Setting window for IC-307
8. If the unit is not connected, press the 1 key, and the Enter key.
To return to the [Remote Box Setup] menu, press the E key (not any numeric key).
9. Repeat step 7 to step 8 for other units not connected.
10. Press the Esc key several times to close the menu.
Setup
System Setup
01:53 02-02-25 (YY-MM-DD)
INMARSAT-C
System Date & Time
IMN
MES Operation Mode
Command Window
[ Main Menu ]
1. Remote Box Setup
2. External Alarm Setup
Enter JOB No.: 1
3. AMS Setup
[ Remote Box Setup ]
1. SSAS OFF
2. IC-305 ON
3. IC-306 No.1 ON
4. IC-306 No.2 OFF
5. IC-306 No.3 OFF
E: Exit
Enter No.:
[ SSAS ]
1. OFF
2. IC-307 (Standard SSAS)
3. IC-307 (Russia SSAS)
4. SSAS(Momentary SW)
E: Exit