4. HOW TO INSTALL OPTIONAL EQUIPMENT
4-2
3. Attach the 51065-0700-PHR7-L110 connector assy. between J13 on the TERM-
CPU Board and J1 on the GPS board.
4. Attach the cable from the GPS board to J6 on the RF COMMCPU Board.
Use the clamp next to the connector to fix the cable.
5. Reassemble the terminal unit.
4.2 IPX2 Kit OP16-58/OP16-59
The optional kits OP16-58 and OP16-59 are used to protect the connectors on the ter-
minal unit from water splash. Note that these optional kits should be used as a pair.
4.2.1 OP16-58 (cables)
Connect the waterproofed D-sub cables to the rear of the terminal unit, instead of the
standard supply cable. For the connection at the IC-318, see section 4.3.
OP16-58 (Code No.: 001-180-070)
Name Type Code No. Qty
Cable Assy. H230817-1 001-176-552-10 1
H230817-2 000-176-553-10 1
XM-FD-361 000-176-551-10 1
GPS board
Binding screw
M3x6, 3 pcs.
J13
J6

Other manuals for Furuno FELCOM18