2. WIRING
2-15
2.9 Control Box Extension Box
The raise/lower control box can be wall mounted up to 5 m away from the hull using
the control box extension box.
1. Disconnect the raise/lower control box from the hull unit.
2. Connect the control box extension box to the hull unit, in the same place the
raise/lower control box was originally connected.
3. Mount the raise/lower control box on a bulkhead within 5 m of the hull unit.
4. Connect the control box extension box to the raise/lower control box, using the
included cables.
Note: When connecting the rotary encoder, limit switch and EMERGENCY STOP
button to the control box extension box, disconnect the connectors from each cable
and replace them with the included crimp-on lugs (See table below for details).
Connect the connectors to the control box extension box cables.
See the Interconnection Diagrams at the back of this manual for information on how
to wire the raise/lower control box and control box extension box.
Crimp-on lug cable connections
Crimp-on lug Cable
FV1.25-3 LMT_SW, Emergency stop button
FV0.5-3 Rotary encoder
200-220 VAC
10CA10053
5 m
SW
M
RE
B
Transceiver
FSV-251
Disconnect the
raise/lower control
box from the hull unit
Raise/lower
control box
FSV-2530
Move fan to
control box
extension box
and install
motion sensor
in control box
extension box
Control box
extension box
FSV-2560
Hull unit
FSV-253/254
Reconnect the
Limit Switch,
Rotary Encoder,
Motor and Brake
to the control box
extension box

Related product manuals