3. POST INSTALLATION SETTINGS
3-11
3.8 Other System Menu Items
This section gives a brief explanation of menu items not previously described.
3.8.1 Interface Setting menu
• [NMEA1/2/3 Baud Rate]: Set the transmission rate for the NMEA 1, NMEA 2 and
NMEA 3 ports. (4800 bps, 9600 bps, 19200 bps, 38400 bps.)
Priority order:NMEA1>NMEA2>NMEA3.
• [CIF1/2 Baud Rate]: Set the transmission rate for the CIF 1 and CIF 2 ports. (2400
bps, 4800 bps, 9600 bps, 19200 bps). Priority order: CIF1>CIF2.
• [EXT KP Input]: Set the input logic of KP from external equipment.
(Disable, Enable) Disable: Disable external KP. Enable: Use KP from external
equipment.
3.8.2 EXT Data Setting menu
• [Date&Time]: Select the input format for date and time data. (NONE, CIF, NMEA)
• [Heading]: Select the input format for heading data. (NONE, AD10, CIF, NMEA)
• [Speed&Course]: Select the input format for ship’s speed and course data.
(NONE, CIF, NMEA)
• [Speed Sensor]: Select the input format for speed data.
(NONE, GPS/DR, DOPPLER/DR) If response is slow, select GPS/DR.
• [Lat/Lon]: Select the input format for position data. (NONE, CIF, NMEA)
• [POS Sensor]: Select the type of the navigator used. Select [Auto Sel] when more
than one navigator is connected.
The priority for auto selection is GPS/DR> Loran-C. (Loran C, GPS/DR, Auto Sel)
• [Water Depth]: Select the input format for water depth. (NONE, CIF, NMEA)
• [Water Temp]: Select the input format for water temperature. (NONE, CIF, NMEA)
• [Water Current]: Select the input format for water current. (NONE, CIF, NMEA)
• [Wind]: Select the input format for wind data. (NONE, CIF, NMEA)
• [Net Depth]: Select the input format for net depth data. (NONE, CIF)
• [CIF Type]: Select the CIF type to use. (CIF-2000, CS-120A)