2. WIRING
2-13
Ground connection
Use a ground wire (IV-8 sq., local supply) to connect to the ship’s earth.
Secure the cables in the cable clamp as shown below.
2.8 Power Supply Unit
Change the connector to the power supply according to the input voltage. Referring to
the figure below, connect the power cable (DPYCY-2.5, supplied locally).
㪈㪇㪚㪘㪈㪇㪇㪉㪐
10CA10028
Transceiver unit (FSV-251)
10CA10053
Motion sensor,
Emergency Stop button*
Limit
Switch*
Limit
Switch*
Rotary
Encoder*
Rotary
Encoder*
TPYCY-4
Ship’s mains
Shaft brake
motor*
10CA10027
10CA10027
Wrap extension box installation
materials DK020FR-19 on cable ends
* Connected to Hull unit (or control box extension box)
123 4567 89
220 V
230 V
0 V
100 V
110 V
0 V
200 V
115 V
0 V
220/230 V 200 V100/110/115 V
100 10
Input
Output
For
230 V
For
115 V
For
110 V
Anticorrosive sheath
Seal cut ends with insulated tape
Clamp the
vinyl sheath
Cores
Measurements shown in mm
Cut the outer sheath and
armor at the same location
L
Cable type
DPYCY-2.5
DPYCY-1.5
Voltage
FV2-5
FV2-4
Length of “L” Crimp-on lug
100/110/115 250
180
180
220/230
200

Related product manuals