The same model of PSUs must be used in a server.
⚫
The PSUs are protected against short circuit. Double-pole fuse is provided for the
PSUs with dual input live wires.
⚫
If the DC power supply is used, purchase the DC power supply that meets the
requirements of the safety standards or the DC power supply that has passed the
CCC certification.
⚫
Contact your local sales representative or use the Compatibility Checker to
determine the components to be used.
⚫
When one or two 900 W AC Titanium PSUs are configured and the input voltage ranges
from 100 V AC to 127 V AC, the output power decreases to 550 W.
⚫
When one or two 1500 W AC Platinum PSUs are configured:
⚫
When the input voltage ranges from 100 V AC to 127 V AC, the output power decreases to
1000 W.
⚫
Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs.
Figure 5-38 PSU positions
5.9 Fans
⚫
The server supports four fan modules.
⚫
The fan modules are hot-swappable.
⚫
The server tolerates failure of a single fan.
⚫
The fan speed can be adjusted.
⚫
The same model of fan modules must be used in a server.