Form Factor | 2U Rack |
---|---|
Processor | Intel Xeon Scalable processors |
Max Processors | 2 |
Memory | DDR4 |
Maximum memory capacity | 3TB |
RAID Support | RAID 0, 1, 10, 5, 50, 6, 60 |
Storage | SAS/SATA/NVMe |
Storage Configurations | 12 x 2.5-inch or 3.5-inch |
Network Ports | Up to 4 x 1GbE or 10GbE ports |
Network | Optional OCP NIC |
PCIe Slots | PCIe 3.0 |
Power Supply | Redundant power supplies |
Power Supply Options | 800W |
Operating Temperature | 5°C to 35°C (41°F to 95°F) |
Memory Slots | 24 |
Describes the FusionServer 2288H V5 rack server's features, structure, and compatibility.
Specifies that the document is intended for pre-sales engineers.
Defines the meaning of symbols used throughout the document.
Details processor capabilities, memory support, and drive configurations for performance.
Covers carrier-class components, hot-swappable drives, and O&M through LEDs and iBMC.
Focuses on iBMC, BIOS password, NC-SI, UEFI, and security features like AES NI.
Discusses 80 Plus Platinum PSUs, VRD, intelligent fan control, and power management.
Details the server's front components, including drive configurations and appearance.
Describes the server's rear components, ports, and indicators.
Information on processor support, installation, and compatibility.
Covers DDR4 and DCPMM memory types, compatibility, and installation rules.
Explains various drive configurations, numbering, and indicators.
Discusses LOMs and FlexIO cards for network expansion.
Details PCIe slots, cards, and riser modules for expandability.
Information on power supply units, including types and redundancy.
Covers fan modules, their hot-swappability, and speed adjustment.
Describes the mainboard and various drive backplanes.
Details component specifications like processor, memory, storage, and network.
Covers operating temperature, humidity, air volume, and noise levels.
Describes dimensions, weight, and installation requirements.
General safety guidelines, human safety, and ESD precautions.
Information on maintenance policy and warranty details.
Lists iBMC features like KVM, virtual media, IPMI, SNMP, Redfish, and login.
Details iBMC specifications for management, fault detection, and watchdog.
Describes chassis labels including front, tail, and internal labels.
Explains the serial number (SN) for device identification and support.
Specifies temperature limits for various server configurations and components.
Details information found on the server's nameplate.
Covers Reliability, Availability, and Serviceability (RAS) features supported by the server.
Lists system sensors, their descriptions, and corresponding components.