FusionServer 2288H V5 Server
Technical White Paper
Copyright © xFusion Digital Technologies Co., Ltd.
can also set it as the iBMC
serial port by using the iBMC
command.
NOTE
The port uses 3-wire serial
communication interface, and the
default baud rate is 115,200 bit/s.
Used for server management.
NOTE
The management network port is a
GE port that supports 100 Mbit/s
and 1000 Mbit/s auto-negotiation.
Used to connect to a USB
device.
NOTICE
Before connecting an external
USB device, check that the USB
device functions properly. The
server may operate abnormally if
an abnormal USB device is
connected.
Used to connect to the power
distribution unit (PDU) in the
cabinet. You can select the
number of power supply units
(PSUs) as required.
NOTE
⚫
When determining the quantity
of PSUs, ensure that the rated
power of the PSUs is greater
than that of the server.
⚫
If only one PSU is used,
Predicted PSU Status cannot
be set to Active/Standby on
the iBMC WebUI.
5.3 Processor
⚫
The server supports one or two processors.
⚫
If only one processor is required, install it in socket CPU1.
⚫
The same model of processors must be used in a server.
⚫
Contact your local sales representative or use the Compatibility Checker to
determine the components to be used.