Page #60 background imageLoading...
Page #60 background image
FusionServer 2288H V5 Server
Technical White Paper
5 Hardware Description
Issue 11 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
54
Figure 5-47 Drive numbering
5.5.3 Drive Indicators
SAS/SATA Drive Indicators
Figure 5-48 SAS/SATA drive indicators
Table 5-14 Description of SAS/SATA drive indicators
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The drive is not in position.
Steady on
Off
The drive is detected.
Blinking at 4 Hz
Off
Data is being read or written normally, or
data on the primary drive is being rebuilt.
Steady on
Blinking at 1 Hz
The drive is being located.
Blinking at 1 Hz
Blinking at 1 Hz
Data on the secondary drive is being
rebuilt.
Off
Steady on
A member drive in the RAID array is
removed.
Steady on
Steady on
The drive is faulty.