FusionServer 2288H V5 Server
Technical White Paper
2 Features
Issue 11 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
4
The BIOS firmware digital signature update mechanism is supported. During
the upgrade, the digital signature is verified to prevent unauthorized BIOS
firmware upgrade.
The flash security protection mechanism is supported to prevent
unauthorized modification of the flash memory in the OS.
The service port with NC-SI enabled supports the following configuration:
Configuring any port on the FlexIO card or PCIe NIC as the service port with NC-SI enabled.
Host port 1 is configured by default.
Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port. The
VLAN ID is 0 and disabled by default.
Configuring IPv4 addresses (IPv4 address, subnet mask, and gateway) and IPv6 addresses
(IPv6 address, prefix length, and gateway) for this port.
Energy Efficiency
The 80 Plus Platinum power supply units (PSUs) of multiple power ratings
provide 94% power efficiency at 50% load.
The server supports active/standby power supplies and high-voltage DC (HVDC)
for improved power supply efficiency.
Efficient voltage regulator-down (VRD) power supplies for boards minimize the
energy loss from DC/DC power conversion.
Area-based, Proportional-Integral-Derivative (PID) intelligent fan speed
adjustment and intelligent CPU frequency scaling optimize heat dissipation and
reduce overall system power consumption.
The improved thermal design with energy-efficient fans ensures optimal heat
dissipation and reduces system power consumption.
The server is protected with power capping and power control measures.
Staggered spin-up for drives reduces the server boot power consumption.
Intel® Intelligent Power Capability allows a processor to be powered on or off
based on requirements.
Low-voltage Intel
®
Xeon
®
Scalable processors consume less energy, ideally
suited for data centers and telecommunications environments constrained by
power and thermal limitations.
SSDs consume 80% less power than HDDs.