EasyManua.ls Logo

Fusion FusionServer 5288 V5 - Environmental Specifications

Fusion FusionServer 5288 V5
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FusionServer 5288 V5 Server
Technical White Paper
6 Product Specifications
Issue 07 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
68
Component
Specifications
operating system is provided.
System management
Supports UEFI.
Supports iBMC.
Supports NC-SI.
Supports integration with third-party management
systems.
Security feature
Power-on password
Administrator password
TCM (only in China)/TPM
Secure boot
Front bezel (optional)
6.2 Environmental Specifications
Table 6-2 Environmental specifications
Category
Specifications
Temperature
Operating temperature: 5°C to 4C (41°F to 104°F)
(ASHRAE Classes A1 to A3 compliant)
Storage temperature (within three months): 30°C to
+60°C (22°F to +140°F)
Storage temperature (within six months): 15°C to
+45°C (5°F to 11F)
Storage temperature (within one year): 10°C to
+35°C (14°F to 9F)
Maximum rate of temperature change: 20°C (36°F) per
hour, 5°C (9°F) per 15 minutes
NOTE
The highest operating temperature varies depending on the
server configuration. For details, see A.3 Operating Temperature
Limitations.
Relative humidity (RH,
non-condensing)
Operating humidity: 8% to 90%
Storage humidity (within three months): 8% to 85%
Storage humidity (within six months): 8% to 80%
Storage humidity (within one year): 20% to 75%
Maximum change rate: 20%/h
Air volume
≥ 273 cubic feet per minute (CFM)
Operating altitude
≤3050m
When the server configuration complies with ASHRAE

Related product manuals