<Model Menu (Airplane/Glider Functions)>
ELEVATOR ELEVATOR 2
FLP 2
(Camber Flap)
FLP 1
(Camber Flap)
85%
CamberFLP to ELE
INH OFF
POS
+0.0%
( +0%) ( +0%)
( +0%) ( +0%)
Linear Separate
+100.0% +100.0%
Model 1
Condition 1
G r.
+150
+100
+50
+0
-50
-150
-100
RATE
Rate A
+0.0%
Offset
Rate B
+0.0%
Fine Tuning
Single
NULL
+ 0%
Rate 1 Rate 2
ELE
ELE2
+0%
+0%
+0% +0%
● Mixing curve setting
● Fine tuning VR setting
●Return to Model Menu
Camber FLP to ELE
[Corresponding model type]: Airplane/glider, 2 ailerons + 1 flap or
more
This mixing is used to correct changes (elevator
direction) generated when the camber aps (speed
aps) are used.
● The elevator servo rates can be adjusted. When
the mix cause the servo direction to be reversed,
adjustments can be made by changing the
mixing rates at - to + (negative to positive).
● A mixing curve can be set.
● Mixing during ight can be turned ON/OFF by
setting a switch. (Always ON at "ON" setting)
● The mixing rate can be ne-tuned by setting a VR.
Touch the [Camber FLP to ELE] button in
the Model Menu to call the setup screen
shown below.
*The display screen is an example. The actual screen
depends on the model type.
●Curve display mode switching
(Single/Fine tuning/All Cond.)
●Elevator rate adjustment
Group/single mode switching
(Gr./Sngl)
● Overall
adjustment
by Rate A
and Rate B
Setting method
● Touch the ACT button and set the function to
ACT(ON).
● When setting a switch, touch the switch button
to call the <Switch> screen, and then select the
switch and set its ON direction. (Always ON at
"ON" setting)
● Touch the elevator servos left and right buttons
and adjust the mixing rate with the adjustment
buttons displayed on the screen.
*When the mixing direction is reversed due to linkage setup,
adjustments can be made by changing the rate value from +
to - (positive to negative).
● When setting a VR, touch the Fine tuning "NULL"
button to call the <Switch> screen, and then
select the VR.
The VR operation mode can be selected.
● A mixing curve can be set.
●The curve operation mode can be changed.
Single : Displays only the mixing curve
Fine Tuning : Displays the adjustment rate of the
ne tuning VR
All Cond. : Displays the mixing curve of all the
conditions (when conditions are set)