EasyManuals Logo

Galil Motion Control DMC-40x0 Series User Manual

Default Icon
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
28 ā— AO DMC-40x0 Command Reference
AO
FUNCTION: Analog Out
DESCRIPTION:
The AO command sets the analog output voltage of Modbus Devices connected via Ethernet.
ARGUMENTS: AO m, n where
m is the I/O number calculated using the following equations:
m = (SlaveAddress*10000) + (HandleNum*1000) + ((Module-1)*4) + (Bitnum-1)
Slave Address is used when the ModBus device has slave devices connected to it and
specified as Addresses 0 to 255. Please note that the use of slave devices
for modbus are very rare and this number will usually be 0.
HandleNum is the handle specifier from A to F.
Module is the position of the module in the rack from 1 to 16.
BitNum is the I/O point in the module from 1 to 4.
n = the voltage which ranges from 9.99 to –9.99
USAGE: DEFAULTS:
While Moving Yes Default Value ---
In a Program Yes Default Format ---
Command Line Yes
Controller Usage
ALL CONTROLLERS
RELATED COMMANDS:
SB Set Bit
CB Clear Bit
MB Modbus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Galil Motion Control DMC-40x0 Series and is the answer not in the manual?

Galil Motion Control DMC-40x0 Series Specifications

General IconGeneral
BrandGalil Motion Control
ModelDMC-40x0 Series
CategoryController
LanguageEnglish

Related product manuals