DMC-40x0 Command Reference CB • 59
CB
FUNCTION: Clear Bit
DESCRIPTION:
The CB command sets the specified output bit low. CB can be used to clear the outputs of
extended I/O which have been configured as outputs.
ARGUMENTS: CB n where
n is an integer corresponding to a specific output on the controller to be cleared (set to 0). The
first output on the controller is denoted as output 1.
USAGE: DEFAULTS:
While Moving Yes Default Value -
In a Program Yes Default Format -
Command Line Yes
Controller Usage
ALL CONTROLLERS
RELATED COMMANDS:
SB Set Bit
OB Output Bit
OP Define output port (byte-wise).
EXAMPLES:
CB 7 Clear output bit 7
CB 16 Clear output bit 16 (8 axis controllers only)
Question and Answer IconNeed help?

Do you have a question about the Galil Motion Control DMC-40x0 Series and is the answer not in the manual?

Galil Motion Control DMC-40x0 Series Specifications

General IconGeneral
CategoryController
SeriesDMC-40x0
Communication InterfaceRS232
Motor Typesstepper
Position FeedbackEncoder
Programming LanguageGalil Motion Language (GML)
Power Supply24 VDC
Operating Temperature0° to +50° C
Storage Temperature-20° to +70° C